Building Automation Systems for Existing Federal Facilities

On Demand Training

3 hours

FEMP e-training

Building Automation Systems for Existing Federal Facilities provides Federal Facility and Energy Managers with the knowledge and competencies to contract for the design and installation a Building Automation System (BAS) in an existing Federal facility, including the ability to apply General Services Administration (GSA) Smart Building Standards into the goal setting process and design objectives.

Learners will explore how to use Building Automation Systems to integrate existing HVAC, lighting, and other systems using normalized data and open communications protocols. The course details a process to set specific performance goals for the BAS, design the BAS to meet the established performance goals, and develop Requests for Proposals for both BAS design and installation. The course also discusses how to maximize the effectiveness of installed BAS to improve building energy efficiency, operations and maintenance, indoor environmental quality, and safety and security.

Learning Objectives

By completing this course you will have a demonstrated knowledge of:

  • Applying GSA Smart Building Standards for open, converged, and normalized building automation;
  • Integrating existing systems through open communication protocols;
  • Making decisions on critical BAS functionality as it applies to: efficiency/cost cutting, indoor environmental quality, operations and maintenance, and safety and security;
  • Identifying results-oriented objectives in development of an RFP;
  • Developing a design plan including sequences of operations, control strategies, schematics, and points lists;
  • Federal and industry standards and guidance related to BAS;
  • Developing RFPs for BAS design and installation;
  • Considering financing mechanisms for the BAS; and
  • Maximizing the installed BAS to improve overall efficiency.

This e-learning course is hosted on the Whole Building Design Guide (WBDG) learning management system. To take the course, click the Start button below. Then log into the WBDG system to launch the course and take the multiple choice assessment. Students will earn .40 IACET CEUs upon successful completion of the course and assessment.

In partnership with Whole Buildings Design Guide, a program of the National Institute of Building Sciences. IACET logo

Instructor(s):

  • Brad Gustafson, Federal Energy Management Program. Read bio.
  • Ed St. Germain, Director of Energy and Environment Support, Enviro-Management & Research, Inc. Read bio.
  • Daniel Ackmann, Enviro-Management and Research, Inc. Read bio.
  • Mohan Jacob, Enviro-Management and Research, Inc.. Read bio.
Take the Training

Help

For more information, contact Beverly Dyer.

Related Courses

You might also be interested in the following course(s):

  • High Efficiency Parking Lighting for Federal Agencies: The Time Is Now to Join LEEP and Get the Resources You Need

    State-of-the-art lighting technology can provide rapid return on investments by reducing energy use 20% to 70%, compared to typical practice. Some have also realized significant reductions in lighting maintenance costs, in part because of the longevity of the new technologies. The Federal Energy Management Program (FEMP) encourages Federal agencies to take advantage of these energy saving lighting systems, and to highlight their commitment and successes by joining the Lighting Energy in Parking (LEEP) Campaign.

  • Advanced HVAC in High-Tech Buildings - Data Centers

    This course covers the best known methods for reducing the energy-intensity of data centers by utilizing server-virtualization, optimizing the temperature within the data center, selecting energy-efficient cooling options, how to arrange server racks and aisles and many other efficiency opportunities. It emphasizes the need for server administrators to work with, rather than independent of facility operators.

Back to Training List