Planning an Energy Assessment for Federal Facilities

On Demand Training

4 hours

FEMP e-training

Focused on managing the Energy Assessment process in federal facilities, this course assists the Federal Energy and Facility Manager to comply with executive orders and legislative mandates and meet the requirements of Section 432 of the Energy Independence and Security Act of 2007. A properly planned and executed energy assessment provides a roadmap for making cost-effective improvements that drive energy and operational efficiencies. This course provides a framework for determining the type of energy assessment to conduct and an overview of how the energy assessment process systemically reviews key facility components including building envelope; mechanical systems such as HVAC; and electrical systems such as lighting. This course focuses on key applications of energy assessments in specific Federal applications such as data centers and laboratories, incorporating best practices and practical advice from experts in Federal energy assessments.

The instructor for this course is Ed St. Germain, Director of Energy and Environment Support at Enviro-Management & Research, Inc. Mr. St. Germain has more than 37 years public and private sector facility, maintenance management, and energy technical assistance experience, specifically in reliability centered maintenance (RCM), retro-commissioning, and energy saving alternatives. During the last twelve years, he has managed long term O&M support contracts, first for NASA Headquarters, and currently for DOE FEMP. He co-authored two EERE O&M handbooks — Commissioning for Federal Facilities (which has an accompanying e-Learning course) and the Energy Savings Assessment Training Manual.

Learning Objectives

By completing this course you will learn to manage the process for conducting an energy assessment in Federal facilities including:

  • selecting the proper energy assessment type and prioritizing the facilities most in need of an energy assessments;
  • understanding how key building components such as building envelope and electrical and mechanical systems are assessed;
  • assembling an energy assessment team with the proper expertise;
  • conducting the energy assessment walkthrough and interviewing key personnel;
  • developing the master list of findings from the energy assessment and prioritizing an operational list of improvements;
  • measurement and verification activities.

The instructor for this course is Ed St. Germain, director of Energy and Environment Support at Enviro-Management and Research, Inc. St. Germain has more than 37 years public and private sector facility, maintenance management, and energy technical assistance experience, specifically in reliability centered maintenance (RCM), retro-commissioning, and energy saving alternatives.

This e-learning course is hosted on the Whole Building Design Guide (WBDG) learning management system. To take the course, click the Start button below. Then log into the WBDG system to launch the course and take the multiple choice assessment. Students will earn .50 FEMP CEUs upon successful completion of the course and assessment.

In partnership with Whole Buildings Design Guide, a program of the National Institute of Building Sciences.

Instructor(s):

  • Ed St. Germain, Director of Energy and Environment Support, Enviro-Management & Research, Inc. Read bio.
Take the Training

Help

For assistance, please contact Beverly Dyer, FEMP training lead, at beverly.dyer@ee.doe.gov or at 202-586-7753.

Related Courses

You might also be interested in the following course(s):

  • Federal Utility Partnership Working Group (FUPWG) Spring Seminar Webinar

    This year’s Spring Federal Utility Partnership Working Group (FUPWG) Seminar will be offered for the first time as a webinar. This is a great opportunity to learn more about FUPWG and FEMP’s Utility Program. We also invite utility contacts to participate and gain a better understanding of the benefits of becoming involved in FUPWG.

  • Goal-Based Contracting for Energy Efficient Buildings

    FEMP First Thursday Seminars provide training for Federal energy and environmental professionals. Leading experts address timely topics in 90-minute sessions, offered live via satellite or through streaming video at your desktop. This seminar will cover ways to implement performance-based contracts that achieve high-performance buildings with low energy profiles. Learn about upfront contract provisions that lead to measurable performance benchmarks in building construction and operations.

Back to Training List