New Developments in Federal Building Energy Efficiency Standards

Live Training

Apr 3, 2014
1:30 p.m. Eastern Time
Video with Audio
FEMP First Thursday Seminar

Gain knowledge of the current legislative drivers relative to ASHRAE standards and which buildings fall under which standard. Learn about major changes in the most recent versions of ASHRAE Standard 90.1 and the International Energy Conservation Code. Understand the actual requirements of the standards, where to look for conservation measures, and how to determine if a building meets them.

Competencies and Objectives

  • When designing a Federal building, determine which Federal Building Energy Efficiency Standards apply for the particular building type.
  • Explain the relationship between the Federal Building Energy Efficiency Standards, ASHRAE 90.1, and the International Energy Conservation Code (IECC).
  • Apply the right parts of the standards (10 CFR 433 and 435) based on when the building design was initiated.
  • When calculating the 30% energy efficiency improvement requirement, explain what is included and excluded in the calculations.
  • Discuss key strategies for meeting the energy efficiency standards through aspects of building design such as building envelope, lighting, service hot water, and technology selection.
  • Discuss key strategies for calculating the improvement, including whole building simulation and life cycle cost analysis.

Credit and Certificate of Completion:

To receive credit for this seminar, register for an account with the Whole Building Design Guide (WBDG) at http://www.wbdg.org/account/register.php.

If you already have a WBDG account, simply log in at http://www.wbdg.org/account/login.php.

Once logged in, visit http://www.wbdg.org/education/fempfts042014.php. Then scroll down, and follow the instructions for taking the assessment and downloading a certificate of completion.

In partnership with Whole Buildings Design Guide, a program of the National Institute of Building Sciences.

Instructor(s):

  • Mark Halverson, Engineer, Pacific Northwest National Laboratory. Read bio.
Before the Training Take the Training
  1. Learner's Guide
  2. Presentation Handout
  3. Facilitator's Guide
Video with Audio

Help

For more information, contact Joe Konrade at joseph.konrade@ee.doe.gov.

Related Courses

You might also be interested in the following course(s):

  • Advanced HVAC in High-Tech Buildings - Data Centers

    This course covers the best known methods for reducing the energy-intensity of data centers by utilizing server-virtualization, optimizing the temperature within the data center, selecting energy-efficient cooling options, how to arrange server racks and aisles and many other efficiency opportunities. It emphasizes the need for server administrators to work with, rather than independent of facility operators.

  • Advanced HVAC in High-Tech Buildings - Laboratories

    This course addresses the six areas that are most responsible for energy waste in laboratories including the air handling systems and fume hoods and provides numerous suggestions for reducing energy use.

Back to Training List