Valencia
Oklahoma City, Oklahoma
Ideal Homes - Oklahoma
Building Science Consortium Mixed - Humid Climate Zone
|
 |
House count for Valencia Community as of November 21, 2009 |
Floor Plan |
Type |
Houses Completed |
Total Buildout |
|
|
|
|
1451
|
Prototype/Research House (G2) |
1 |
1 |
|
2314
|
Prototype/Research House (G2) |
1 |
1 |
|
1644
|
Prototype/Research House (G2) |
1 |
1 |
Totals: |
183 |
211 |
 |
Floor Plan 1644 |
 |

|
~Legend~
General Information
BA PERCENT ENERGY SAVINGS: 88%
HERS RATING:
ENERGY STAR RATING:
OTHER AWARDS:
OTHER EE UPGRADES:
FLOOR AREA: 1644
STYLE: Single-family detached, site built
STORIES: 1
A: Roofing Components
ROOF FRAMING: Vented attic - truss framing
ROOF R-VALUE: 38.0
B: Window Components
WINDOW GLAZING: Double pane - low-e - argon filled
WINDOW FRAMING: Vinyl
WINDOW U-VALUE: 0.39
WINDOW SHGC VALUE: 0.31
C: Space Heating Components
SPACE HEATING TYPE: Air Source Heat Pump
SPACE HEATING COMBUSTION: Not Applicable
SPACE HEATING EFFICIENCY: 14.0
HSPF
D: Foundation Components
FOUNDATION TYPE: Slab on grade
FOUNDATION INSULATION: Rigid foam
SLAB INSULATION: 4
E: Hot Water Components
HOT WATER TYPE: Gas - tank
HOT WATER LOCATION: Garage
HOT WATER ENERGY FACTOR: 27
F: Air Distribution Components
AIR HANDLER LOCATION: Interior closet
DUCT LOCATION: In unconditioned space
VENTILATION TYPE: Heat Recovery Ventilator (HRV)
G: Air Conditioning Components
COOLING TYPE: Air Source Heat Pump
COOLING SEER: 20.0
H: Wall Components
WALL FRAMING: Wood - 2x6 - 24 in o.c. (Advanced Framing)
WALL R-VALUE: 19.0
WALL SHEATHING R-VALUE: 3.0
|
 |
 Example Ideal Homes high performance home |
 |